Be the first to review this product

Testo
330-1 LL - Flue Gas Analyser


Testo 330-1 LL Flue Gas Analyser designed for the domestic & commercial heating systems with long-life sensors. Many measurement menus for analysis on heating systems, incl. solid fuel and gas pipe test menus.

Part Number:
0563 3371 70

read more

 



List Price

£1499.00
1798.80 incl. VAT)
Add To Cart

 

 

 

Testo 330-1 LL Flue Gas Analyser

Testo 330-1 LL Flue Gas Analyser with Bluetooth, ideal for customer service and maintenance engineers, designed for the domestic and commercial heating systems.

Carry out your service and maintenance inspections quickly and efficiently, combining sophisticated sensor technology and a high level of safety with a long product life span and easy handling.

 

▶ Testo 330 Longlife Sensor Gas Analyser Application Video:

 

▶ Testo 330 Longlife Sensor Gas Analyser Overview:

 

Testo 330-1 LL Key Features: 

  • Rugged and easy-to-use
  • Many measurement menus for analysis on heating systems, incl. solid fuel and gas pipe test menus
  • Integrated magnets that stick to almost any metal object for easy measuring
  • Easy-to-empty condensate collection tank
  • Two high-quality sensors for O2 and CO (without H2 compensation)
  • Ambient CO measurement with 15-minute mean value calculation through standard flue gas probe
  • High-resolution graphic colour display, graphic presentation of the course of the measurement with flue gas matrix and line diagram
  • Integrated sensor monitoring, traffic light colour coding system and at-a-glance status
  • Logger function for up to two hours of continuous measurements
  • Super-size memory for up to 500,000 readings
  • Flue gas probe connector for quick, easy and safe probe attachment
  • Long-life sensors with up to 6 years‘ service life
  • TÜV-tested
  • 4-year warranty without maintenance contract

 

Testo 330-1 LL Perfect For The Following Applications:

  • Ambient CO measurement in the heated environment
  • Measuring pressure on burners (nozzle pressure, gas flow pressure, etc.)
  • Measuring the flue gas parameters of the burner (CO, O2, and temperature, etc.)
  • Measuring temperatures on radiators

 

What comes with the 330-1 LL?

  • Testo 330-1 LL - Flue Gas Analyser with long-life gas sensors
  • Rechargeable battery
  • Mains charging unit (0554 1096)
  • Calibration protocol
  • Flue gas probe (180mm x 6mm)
  • Carry case


Require a printer? Call: 01782 563030 quoting part number 0554 0549 for the optional Infrared Printer

 

Comparison Chart for: Testo 330-1 LL - Flue Gas Analyser

330-1 LL330-2 LL
Differential Pressure - Piezoresistive
Measuring range0 to +300 hPa±10000 Pa
Accuracy±0.5 hPa (0.0 to 50.0 hPa)±0.3 Pa (0 to 9.99 Pa) plus ±1 Digit
±1 % of mv (50.1 to 100.0 hPa)±3 % of mv (10 to 10000 Pa) plus ±1 Digit
±1.5 % of mv (Remaining Range)
Flue gas O₂
Measuring range0 to 21 Vol.%0 to 21 Vol.%
Accuracy±0.2 Vol.%±0.2 Vol.%
Resolution0.1 Vol.%0.1 Vol.%
Reaction time t₉₀< 20 s< 20 s
Flue gas CO (with H₂-compensation)
Measuring range0 to 8000 ppm0 to 8000 ppm
Accuracy±10 ppm or ±10 % of mv (0 to 200 ppm)±10 ppm or ±10 % of mv (0 to 200 ppm)
±20 ppm or ±5 % of mv (201 to 2000 ppm)±20 ppm or ±5 % of mv (201 to 2000 ppm)
±10 % of mv (2001 to 8000 ppm)±10 % of mv (2001 to 8000 ppm)
Resolution1 ppm1 ppm
Reaction time t₉₀< 60 s< 60 s
Flue gas COlow
Measuring range0 to 500 ppm0 to 500 ppm
Accuracy±2 ppm (0 to 39.9 ppm)±2 ppm (0 to 39.9 ppm)
±5 % of mv (40 to 500 ppm)±5 % of mv (40 to 500 ppm)
Resolution0.1 ppm0.1 ppm
Reaction time t₉₀< 40 s< 40 s
CO determination (with H₂-compensation), automatic dilution
Measuring range 0 to 30000 ppm
Accuracy±100 ppm (0 to 1000 ppm)
±10 % of mv (1001 to 30000 ppm)
Resolution1 ppm
Flue gas NO
Measuring range0 to 3000 ppm0 to 3000 ppm
Accuracy±5 ppm (0 to 100 ppm)±5 ppm (0 to 100 ppm)
±5 % of mv (101 to 2000 ppm)±5 % of mv (101 to 2000 ppm)
±10 % of mv (2001 to 3000 ppm)±10 % of mv (2001 to 3000 ppm)
Resolution1 ppm1 ppm
Reaction time t₉₀< 30 s< 30 s
Flue gas Nolow
Measuring range0 to 300 ppm0 to 300 ppm
Accuracy±2 ppm (0 to 39.9 ppm)±2 ppm (0 to 39.9 ppm)
±5 % of mv (40 to 300 ppm)±5 % of mv (40 to 300 ppm)
Resolution0.1 ppm0.1 ppm
Reaction time t₉₀< 30 s< 30 s
Flue gas Draught
Measuring range-9.99 to +40 hPa-9.99 to +40 hPa
Accuracy±0.02 hPa or ±5 % of mv (-0.50 to +0.60 hPa)±0.02 hPa or ±5 % of mv (-0.50 to +0.60 hPa)
±0.03 hPa (+0.61 to +3.00 hPa)±0.03 hPa (+0.61 to +3.00 hPa)
±1.5 % of mv (+3.01 to +40.00 hPa)±1.5 % of mv (+3.01 to +40.00 hPa)
Resolution0.01 hPa0.01 hPa
Temperature
Measuring range-40 to +1200 °C *-40 to +1200 °C
Accuracy±0.5 °C (0 to +100.0 °C)±0.5 °C (0 to +100.0 °C)
±0.5 % of mv (Remaining Range)±0.5 % of mv (Remaining Range)
Resolution0.1 °C (-40 to +999.9 °C)0.1 °C (-40 to +999.9 °C)
1 °C (> +1000 °C)1 °C (> +1000 °C)
* Measuring range depends on the connected flue gas probe
Flue gas degree of effectivity, Eta (calculated)
Measuring range0 to 120 %0 to 120 %
Resolution0.10%0.10%
Flue gas loss (calculated)
Measuring range0 to 99.9 %0 to 99.9 %
Resolution0.10%0.10%
Flue gas CO₂ calculation (calculated from O₂)
Measuring range0 to CO₂ max (Display range)0 to CO₂ max (Display range)
Accuracy±0.2 Vol.%±0.2 Vol.%
Resolution0.1 Vol.%0.1 Vol.%
Reaction time t₉₀< 40 s< 40 s
Velocity / Volume flow
Measuring range0.15 to 3 m/s
Resolution 0.1 m/s
Pressure measurement
Measuring range0 to +300 hPa0 to +300 hPa
Accuracy±0.5 hPa (0.0 to 50.0 hPa)±0.5 hPa (0.0 to 50.0 hPa)
±1 % of mv (50.1 to 100.0 hPa)±1 % of mv (50.1 to 100.0 hPa)
±1.5 % of mv (Remaining Range)±1.5 % of mv (Remaining Range)
Resolution0.1 hPa0.1 hPa
Flue gas CO (without H₂-compensation)
Measuring range0 to 4000 ppm0 to 4000 ppm
Accuracy±20 ppm (0 to 400 ppm)±20 ppm (0 to 400 ppm)
±5 % of mv (401 to 2000 ppm)±5 % of mv (401 to 2000 ppm)
±10 % of mv (2001 to 4000 ppm)±10 % of mv (2001 to 4000 ppm)
Resolution1 ppm1 ppm
Reaction time t₉₀< 60 s< 60 s
Ambient CO
Measuring range0 to 500 ppm0 to 500 ppm
Accuracy±5 ppm (0 to 100 ppm)±5 ppm (0 to 100 ppm)
±5 % of mv (> 100 ppm)±5 % of mv (> 100 ppm)
Resolution1 ppm1 ppm
Reaction timeApprox. 35 sApprox. 35 s
with CO probe 0632 3331
Ambient CO₂
Measuring range0 to 1 Vol.%0 to 1 Vol.%
0 to 10000 ppm0 to 10000 ppm
Accuracy±75 ppm or ±3 % of mv (0 to 5000 ppm)±50 ppm or ±2 % of mv (0 to 5000 ppm)
±150 ppm or ±5 % of mv (5001 to 10000 ppm)±100 ppm or ±3 % of mv (5001 to 10000 ppm)
Reaction timeApprox. 35 sApprox. 35 s
with ambient CO₂ probe 0632 1240
Gas leak measurement for combustible gases (via gas leak detection probe)
Measuring range0 to 10000 ppm CH₄ / C₃H₈; Display range0 to 10000 ppm CH₄ / C₃H₈; Display range
AccuracySignal optical display (LED) audible signal via buzzerSignal optical display (LED) audible signal via buzzer
Reaction time t₉₀< 2 s< 2 s
with gas leak detection probe
Temperature (via the fine pressure probe)
Measuring range-40 to +1200 °C max. (dependent on probe)
Accuracy±0.5 °C (-40 to 100 °C)
±0.5 % of mv (Remaining Range) plus probe accuracy
Resolution0.1 °C
General technical data
Dimensions270 x 90 x 65 mm270 x 90 x 65 mm
Operating temperature-5 to +45 °C-5 to +45 °C
Display size240 x 320 pixels240 x 320 pixels
Display functionColour graphic displayColour graphic display
Power supplyRechargeable battery pack 3.7 V / 2.6 Ah; Mains unit 6 V / 1.2 ARechargeable battery pack 3.7 V / 2.6 Ah; Mains unit 6 V / 1.2 A
Maximum memory500,000 readings500,000 readings
Storage temperature-20 to +50 °C-20 to +50 °C
Weight600 g (without rechargeable battery)600 g (without rechargeable battery)