• approved distributor

    Buy or Hire Test Equipment
    Repair | Calibrate | Training

  • product advice and demos

    Product advice & demos
    Aftersales support

  • competetive prices

    Competitive quotes
    Bespoke deals

  • approved distributor

    Approved distributor
    Approved service centre

 

Be the first to review this product

Megger
FRAX 99 Sweep Frequency Response Analyser


Megger FRAX Sweep Frequency Response Analyser (SFRA) collects fingerprint data using Frequency Response Analysis (FRA), an easy way to detect electro-mechanical problems in power transformers & an investment that will save time & money

Part Number:
AC-29095

read more

 

Need Help ? Contact Us Request Demo Browse Accessories
Acutest's Price Promise
  • Competitive quote
  • Expert technical advice/demos
  • Trusted aftercare support

Product Options

 

Price On Request

  • Competitive quote
  • Expert technical advice/demos
  • Trusted aftercare support

 

free_product_trial_badge_85pix

ENJOY A FREE PRODUCT TRIAL OF ANY FLUKE, FLIR, MEGGER OR CHAUVIN ARNOUX (OVER £1000). Risk-free/No hard-sell. To enquire CLICK HERE.

 

 

Megger FRAX Sweep Frequency Response Analyser

Power transformers are some of the most vital components in today’s transmission and distribution infrastructure. Transformer failures cost enormous amounts of money in unexpected outages and unscheduled maintenance. It is important to avoid these failures and make testing and diagnostics reliable and efficient.

The FRAX series of sweep frequency response analysers (SFRA) detects potential mechanical and electrical problems that other methods are unable to detect. Major utilities and service companies have used the ‘FRA‘ method for more than a decade.  The measurement is easy to perform and will capture a unique fingerprint of the transformer.  The measurement is compared to a reference fingerprint and gives a direct answer if the mechanical parts of the transformer are unchanged or not.  Deviations indicate geometrical and/or electrical changes within the transformer.  FRAX is an investment that will save time and money!

Most dielectric and mechanical failures in large power transformers are preceded by mechanical changes in the winding structure.  These displacements in the winding structure may be the result of transportation damage, short circuit forces, or natural aging effects on the insulating structures used to support the windings.  Detection of these displacements before dielectric failure reduces maintenance costs, and improves system reliability.  FRAX Sweep Frequency Response Analyser (SFRA) is designed to detect winding displacements in power transformers or faults in the magnetic core.


 

Megger FRAX Key Features:

  • Designed for medium and high-voltage substations and industrial environments
  • Highest dynamic range and accuracy in the industry„
  • Fulfills international standards for SFRA measurements„
  • Advanced analysis and decision support built into the software. FRAX 150 with built in PC and touchscreen„
  • Imports data from other FRA test sets„
  • Wireless communication (FRAX 101)„
  • Battery operated (optional FRAX 99 and FRAX 101)„
  • Continuity control of ground connections (FRAX 101 and 150)

 

Megger FRAX Detects:

  • Winding deformations and displacements
  • Shorted turns and open windings
  • Broken clamping structures
  • Core connection problems
  • Partial winding collapse
  • Faulty core grounds
  • Core movements

 

Technical Specification for: Megger FRAX 99 Sweep Frequency Response Analyser

FRAX 99FRAX 101FRAX 150
Output voltage20 V0.2-24 V0.2-24 V
Measurement voltage10 V @ 50 Ω0.1-12 V @ 50 Ω0.1-12 V @ 50 Ω
Frequency range0.1 Hz – 25 MHz0.1 Hz – 25 MHz0.1 Hz – 25 MHz
Frequency sweep settings
Low to high or high to low, logarithmic or linear
Number of pointsDefault 1046, user selectable up to 32000Default 1046, user selectable up to 32000Default 1046, user selectable up to 32000
Dynamic range (IEC60076-18) (+ 10 dB to internal noise level)> 130 dB> 150 dB> 150 dB
Accuracy± 1 dB from +10 dB to -100 dB± 0.1 dB from +10 dB to -50 dB± 0.1 dB from +10 dB to -50 dB
± 0.5 dB from +10 dB to -100 dB± 0.5 dB from +10 dB to -100 dB
Analysis
Magnitude
Phase
Impedance
Admittance
Inductance
Resistance
User defined formulas to the list of analysis toolsCross-correlation (CCF), as in DL/T911-2004 or customer definedCross-correlation (CCF), as in DL/T911-2004 or customer definedCross-correlation (CCF), as in DL/T911-2004 or customer defined

 

Accessory Code Description Price (Ex VAT)
AC-90020 FRAX Calibration Set price on request
AC-90050 FDB-101: FRAX Demo Box price on request
GC-30040 FRAX Generator Cable 9m: 2xBNC price on request
GC-30042 FRAX Generator Cable 18m: 2xBNC price on request
GC-30050 FRAX Measure Cable 9m: 1xBNC price on request
GC-30052 FRAX Measure Cable 18m: 2xBNC price on request
GC-80010 FRAX C-clamp price on request

 

 