Bowdens
Omega 4 Earth Fault Indicator (RTU/DC Powered with Battery)


Explore the Bowdens OMEGA 4 EFI Fault Passage Indicator with optional overcurrent detection, directional indication & 4G. Request a quote from AcutestDirect.

Part Number:
BOW OM4 RTU BAT

read more

 

Need Help ? Contact Us Request Demo
Acutest's Price Promise
  • Competitive quote
  • Expert technical advice/demos
  • Trusted aftercare support

Product Options

 

Manufacturer's RRP

£286.65
343.98 incl. VAT)
Add To Cart
  • Competitive quote
  • Expert technical advice/demos
  • Trusted aftercare support

 

 

 

Bowdens OMEGA 4 Fault Passage Indicator

Gain clearer visibility of underground cable faults with the Bowdens OMEGA 4 fault passage indicator (FPI). Designed to help engineers identify faulted network sections, the OMEGA 4 combines local alarm indication, programmable detection settings and remote indication facilities in a modular instrument.

Specify a single-channel earth fault indicator or a configuration with three-phase overcurrent and earth fault detection. Directional indication and communications options extend its capabilities, supporting applications from local fault indication to connected network monitoring.

An LCD display and four-button interface provide access to operating data, settings and test functions. PIN-protected programming helps control access to configuration changes, while stored last-fault information supports investigation after an event.

Request a competitive quote for the Bowdens Omega 4 EFI today.



Diagram of the Bowdens OMEGA 4 EFI

 

Bowdens OMEGA 4 Key Features:

  • Support fault location: Indication of fault-current passage helps engineers narrow down the affected section of an underground cable network.
  • Choose your detection configuration: Earth fault, overcurrent and combined detection modes are available according to the configuration specified.
  • Clear local indication: Dedicated earth fault and overcurrent LEDs, a digital flag indicator and an LCD display present alarm and operating information.
  • Programmable detection: Set current thresholds and trip delays to match your application and compatible current transformers.
  • Directional indication option: Left/right arrows show fault direction when the unit is configured with a suitable voltage reference.
  • Remote indication and reset: Standard facilities support operation beyond the front panel, complemented by two sets of isolated volt-free alarm contacts.
  • Optional communications: Specify 4G mobile connectivity or Modbus RTU over RS485 to support remote monitoring and system integration.
  • Retained fault information: Last-fault data remains stored after power cycling, until the next detected fault replaces it.

 

Specifications:

Features 
Detection and control
Earth fault trip currentSelectable settings from 20 to 120 A; available range depends on CT ratio
Overcurrent trip currentSelectable settings from 125 to 750 A on configurations supporting overcurrent detection
Earth fault and overcurrent trip delaysSelectable settings from 20 to 200 ms
Timed resetSelectable from 1 to 12 hours
Reset methodsManual, timed and remote; LV reset requires the power supply board
Alarm outputsTwo sets of isolated volt-free contacts: normally open, common and normally closed
Relay modesLatched, pulsed or multi-detect, including indication of subsequent faults while an alarm remains active
Manual alarm test✓ Accessible through the front-panel menu
PIN-protected settings
Power options
OMEGA 4 BATIntegral 3.6 V, 13 Ah lithium thionyl chloride battery
Battery lifeUp to 10 years, depending on operational usage and environmental temperatures
OMEGA 4 LV230 V AC mains power with a power supply board; a 3.6 V, 13 Ah battery is still required
OMEGA 4 RTU12 V or 24 V DC supply from an RTU
Communications and construction
Mobile communicationsOptional 4G connectivity
Serial communicationsOptional Modbus RTU over RS485
LoRa radioSupports peer-to-peer and peer-to-relay communication
Enclosure materialPolycarbonate
Operating temperature-25°C to +70°C

 

Available OMEGA 4 variants

Choose the Bowdens OMEGA 4 configuration that suits your installation, with battery, LV and RTU/DC powered options. LTE variants include 4G communications, while SC variants provide supercapacitor operation without a battery.

Product codePower configuration4G communications
Battery powered and battery-backed variants
BOW OM4 BATBattery poweredOptional
BOW OM4 LV BATLV powered with batteryOptional
BOW OM4 RTU BATRTU/DC powered with battery; PSU includedOptional
Variants with 4G communications
BOW OM4 BAT LTEBattery powered✓ Included
BOW OM4 LV BAT LTELV powered with battery✓ Included
BOW OM4 RTU BAT LTERTU/DC powered with battery; PSU included✓ Included
Battery-free supercapacitor variants
BOW OM4 LV SCLV powered with supercapacitor; no batteryOptional
BOW OM4 RTU SCRTU/DC powered with supercapacitor; no batteryOptional

Extended communications options include Modbus over RS485 and LoRa or LoRaWAN. Contact AcutestDirect to specify your required power supply and communications configuration.

 

Selecting your OMEGA 4 configuration

Earth fault-only operation uses a compatible core balance current transformer. Combined overcurrent and earth fault detection requires three individual phase CTs, with a 500:1 CT ratio required for overcurrent detection.

Directional indication requires a suitable LV or VPIS voltage reference and consistent CT orientation and polarity across the installation. Specify your detection functions, power supply, CT arrangement and communications requirements when ordering.

 

Turn fault indication into useful network information

From local earth fault indication to directional detection and remote reporting, the Bowdens OMEGA 4 offers configurations to suit different network monitoring needs. Give engineers clearer information to support fault location and isolation decisions, with adjustable settings and practical local controls. Contact AcutestDirect to discuss your application and request a quote for the right configuration.

Note: Be sure to check the official datasheet before buying, and the user manual before using any test equipment. Need training? Just reach out - we’re happy to help.

 