• approved distributor

    Buy or Hire Test Equipment
    Repair | Calibrate | Training

  • product advice and demos

    Product advice & demos
    Aftersales support

  • competetive prices

    Competitive quotes
    Bespoke deals

  • approved distributor

    Approved distributor
    Approved service centre

 

Be the first to review this product
(0)

Chauvin Arnoux
PEL113 Power Logger


Discover the Chauvin Arnoux PEL113 Power Logger: compact, versatile, & ideal for optimising energy use, monitoring systems, & enhancing performance.

Part Number:
P01157157

read more

 

Need Help ? Contact Us Request Demo
Acutest's Price Promise
  • Competitive quote
  • Expert technical advice/demos
  • Trusted aftercare support

 

Manufacturer's RRP

£2332.00
2798.40 incl. VAT)
Add To Cart
  • Competitive quote
  • Expert technical advice/demos
  • Trusted aftercare support

 

 

 

Chauvin Arnoux PEL113 Power Logger

  • Professional power and energy analysis made simple

The Chauvin Arnoux PEL113 Power Logger is a small and flexible device. It is designed for accurate energy measurement and logging in low-voltage electrical networks. The PEL113 is made for electricians, energy auditors, facility managers, and maintenance teams. It is great for analysing energy use, finding inefficiencies, and helping meet energy management standards.

 

Chauvin Arnoux PEL113 Power & Energy Logger

 

Chauvin Arnoux PEL113 Key Features:

  • Single-phase, split-phase, and three-phase network compatibility
  • Real-time measurements of voltage, current, power, and energy
  • Automatic recognition of current sensors
  • Compact and rugged housing for industrial environments
  • USB, Bluetooth, Ethernet and SD card data export options
  • Class 0.5 accuracy for energy readings

The Chauvin Arnoux PEL113 stands out because of its user-friendly interface and non-intrusive installation. It lets you track and record energy data all the time. You don‘t need to turn off the system. This is important for busy sites that need constant service.

 

Why Choose the Chauvin Arnoux PEL113?

For professionals who manage or audit energy use, the PEL113 offers great performance, accuracy, and convenience. Engineers designed it as a power energy logger to capture critical data across a range of electrical installations.

The Chauvin Arnoux PEL113 Power Logger is useful for everyone. It works well in commercial buildings. It is also effective in industrial plants and data centers. It can find inefficiencies and lower energy costs.

Thanks to its compact design and magnetised casing, the PEL113 can be mounted directly onto electrical cabinets—even when space is limited. The device automatically detects and adjusts to different sensor types, saving time during setup and reducing the chance of configuration errors.

 

Comprehensive Measurement Capabilities

The Chauvin Arnoux PEL113 is capable of simultaneously measuring:

  • Voltage (RMS): up to 1000 V
  • Current (RMS): depending on the clamp used
  • Power: Active, reactive, and apparent
  • Power factor: including displacement power factor
  • Energy consumption: kWh, kvarh, kVAh
  • THD (Total Harmonic Distortion) and harmonics up to the 50th order

With its high sampling rate and Class 0.5 accuracy for energy measurements, the PEL113 provides trusted performance for professionals who require dependable results when assessing electrical network health and efficiency.

 

Easy Data Retrieval and Analysis

Data logging and retrieval are effortless with the Chauvin Arnoux PEL113 Power Logger. Data can be stored on an SD card and transferred via USB, Ethernet, or Bluetooth for convenient analysis. The logger is compatible with Chauvin Arnoux’s PEL Transfer software, which enables users to analyse trends, compare historical usage patterns, and generate professional energy reports suitable for clients or internal documentation.

This power energy logger can also be accessed remotely, enabling engineers to monitor sites in real-time without being physically present—particularly useful for hard-to-reach or critical locations where downtime is not an option.

 

Automatically Recognises Sensor Types

One of the standout features of the Chauvin Arnoux PEL113 is its ability to automatically recognise connected current sensors. This intuitive capability significantly streamlines the setup process and enhances accuracy by ensuring the correct configuration from the outset.

This makes the PEL113 highly adaptable for use across a broad range of electrical networks, from basic single-phase setups to complex three-phase systems. Whether you‘re testing energy usage in an office, manufacturing facility, or retail complex, the Chauvin Arnoux PEL113 Power Logger ensures you capture the data you need efficiently and correctly.

 

Built for Tough Environments

Designed with rugged field use in mind, the PEL113 has an IP54-rated enclosure and is resistant to dust and splashing water. It performs reliably in industrial settings, machine rooms, and environments with fluctuating temperature or humidity levels.

Installation is also safe and efficient. The Chauvin Arnoux PEL113 is designed for use without shutting down electrical systems, allowing professionals to install the logger on live circuits, reducing downtime and operational disruption.

 

Versatile Applications

  • Energy audits – Track and assess energy consumption for compliance or cost-saving measures.
  • Preventative maintenance – Detect anomalies or irregularities in power usage before they lead to equipment failure.
  • System upgrades – Measure load profiles to support capacity planning and infrastructure upgrades.
  • Power quality analysis – Identify harmonics, imbalances, and other factors affecting system performance.

The PEL113 is equally suited for short-term surveys and long-term monitoring, providing flexibility and value no matter your project duration.

 

Technical Specifications:

FeatureSpecification
Voltage Measurement Range10 V to 1000 V RMS
Current RangeDepends on clamp model (e.g., MN, C, MA, A models)
Power MeasurementActive, reactive, and apparent
AccuracyClass 0.5 for energy
THD & HarmonicsUp to 50th harmonic
MemorySD card (supplied)
Communication InterfacesUSB, Ethernet, Bluetooth
Power Supply100–250 V AC / 120–250 V DC
Protection RatingIP54
Operating Temperature-20 °C to +55 °C
Dimensions175 x 125 x 55 mm
Weight1.3 kg

 

Enhance Your Energy Strategy with the PEL113

The Chauvin Arnoux PEL113 Power Logger empowers professionals to make informed, data-driven decisions. With precise monitoring of energy consumption, the PEL113 helps reduce waste, enhance efficiency, and ensure compliance with energy standards. Whether you’re conducting an energy audit, troubleshooting an electrical installation, or planning an upgrade, the PEL113 offers all the insight you need in a compact, field-ready format.

Its non-intrusive, safe-to-install design, high compatibility with multiple electrical network types, and seamless software integration make it one of the most trusted tools in the market for power energy logging.

 

 Connections on top of the Chauvin Arnoux PEL113

 

Sectors which find the PEL113 useful!

The PEL113 measures and records all power and energy values.

It can be used wherever there is electricity:

  • Electricity generator: renewable, thermal, etc.
  • Industries: metallurgy, glassmaking, agri-food
  • Residential buildings, tertiary, etc.
  • Infrastructure and transport
  • Datacenters

Applications:

  • Energy audits
  • Electrical diagnostics
  • Industrial maintenance

 

 

What comes with the Chauvin Arnoux PEL113?

  • Chauvin Arnoux PEL113 Power Logger
  • Carrying case
  • 4 x voltage cables
  • 4 x crocodile clips
  • 1 x set of inserts/ rings
  • SD card
  • SD Card-USB adapter
  • USB cable
  • Mains cable
  • PEL TRANSFER PC software
  • Quick start guide

 


 

PEL113 Software and Communications

PEL Transfer Software:

With the PEL Transfer software, you can:

  • Set up your PEL
  • Check connections before recording
  • Download recorded measurements
  • View results and analyses
  • Additional advantage: converts electricity consumption into local currency (€, £, $, etc.) with 8 tariff ranges.

 

Communication and Networks:

The PEL 110 models support multiple communication modes:

  • USB; the simplest for local use
  • Ethernet RJ45 or Wi-Fi (server); allows connection to a server for remote access via the PEL Transfer software
  • Wi-Fi (Access Point); Perfect for a direct link between the PEL11x and your computer (supports up to 5 clients)

 

Order the Chauvin Arnoux PEL113 Today

If you‘re looking for a powerful, reliable, and intelligent power energy logger, the Chauvin Arnoux PEL113 Power Logger is a professional-grade solution built to meet the demands of modern energy analysis.

Place your order today and start unlocking the benefits of precise energy consumption measurement and network diagnostics.

 

Technical Specification for: Chauvin Arnoux PEL113 Power Logger

 

 

 

ONLY REGISTERED USERS CAN WRITE REVIEWS. PLEASE SIGN IN OR CREATE AN ACCOUNT