Druck
UPS-III Loop Calibrator


Druck UPS-III 24mA Loop Calibrator with easy-read display & compact enough to fit comfortably in a shirt pocket. Measure or source 0 to 24mA with a accuracy 0.01% of reading...

Part Number:
UNO-UPS-III

read more

 

Need Help ? Contact Us Request Demo
Acutest's Price Promise
  • Competitive quote
  • Expert technical advice/demos
  • Trusted aftercare support

 

DISCONTINUED

  • Competitive quote
  • Expert technical advice/demos
  • Trusted aftercare support

 

 

 

Druck UPS-III 24mA Loop Calibrator

This compact, lightweight device if full of simple time-saving features; perfect for loop calibration and troubleshooting, instrument maintenance, and valve set-up.

The measure / source range for the loop calibrator is 0 to 24mA. In addition, 0 to 60Vdc can be measured for loop diagnostics and voltage output instrument maintenance. The accuracy of the GE Druck UPS III loop calibrator is 0.01% of reading, which is 20 times better than a typical DMM, and includes 12 month stability and temperature effects. Coupled with 0.001mA display resolution, the GE Druck UPS III loop calibrator provides optimum measurement certainty for even the most demanding applications.

A broad range of specific time-saving features are enabled by the GE Druck UPS III loop calibrator’s advanced microprocessor-based electronics and large menu-driven graphic display, unique in a product of this type and price. Features of the GE Druck UPS III loop calibrator include, for example, simultaneous mA/% value readout, either linear or percentage flow conversion. Step, span, and valve checks allow the user to step quickly through the GE Druck UPS III loop calibrator’s linearity tests and zero / span adjustments. In valve mode, valve seating can be checked and the positioner set.


Druck UPS III Key Features:

  • Easy to read graphical display
    • with adjustable display contrast
  • Measure or Source 0 to 24mA
  • Accuracy 0.01% of reading
  • Dual mA and % readout, linear or flow
  • Step, Span Check, Valve Check, Ramp
  • 60 V DC measurement and continuity
  • HART compatible with internal loop resistor
  • Continuity and Switch Test Facility
  • Display serial number, software version, and calibration date
  • Primary reading in mA or %
  • Optional protective over-boot with bench stand, hanging loop and quick connect belt clip
  • EMC compliance to EN 61326-1
  • Uses industry standard AA batteries
    • Battery voltage and battery low indicator
  • Pin protected closed case calibration
  • Optional AC line adaptor
  • Auto power off (enable or disable)
  • Measures only 77 x 129mm
  • Weighing just 275g


What comes with the Druck UPS III?

  • Druck UPS-III 24mA Loop Calibrator
  • Certificate of calibration
  • User guide
  • Test leads
  • Set of alkaline batteries


 

Technical Specification for: Druck UPS-III Loop Calibrator

 

 

 