Fluke
28 II Ex Intrinsically Safe Digital Multimeter


FLUKE 28 II Intrinsically Safe True-RMS Digital Multimeter designed for industrial troubleshooting in explosive environments. Solving problems on motor drives, in plant automation, power distribution & electromechanical equipment complete with a 4-1/2 digit mode for precise measurements & measures up to 1000V and 10A ac and dc.

Part Number:
FLUKE-28IIEX

read more

 

Need Help ? Contact Us Request Demo Browse Accessories
Acutest's Price Promise
  • Competitive quote
  • Expert technical advice/demos
  • Trusted aftercare support

 

£1,579.00
£1288.00
1545.60 incl. VAT)
Add To Cart
  • Competitive quote
  • Expert technical advice/demos
  • Trusted aftercare support

 

 

 

FLUKE 28 II Ex Intrinsically Safe Digital Multimeter

FLUKE products designed to intrinsic safety standards - A protection method employed in potentially explosive atmospheres, intrinsically safe devices are designed to be unable to release sufficient energy, by either thermal or electrical means, to cause ignition of flammable material (gas or dust/particulates).

Potentially explosive atmospheres can be found in a variety of manufacturing environments from chemical or pharmaceutical processing, to oil refineries, or any environment where flammable material (gas or dust/particulates) are present.  FLUKE’s intrinsically safe test tools can be used to help you perform maintenance and calibration tasks in potentially explosive and hazardous classified areas.

FLUKE 28 II equips you with all the testing and troubleshooting power you need wherever you go (inside or outside ATEX zones 1,2,21, or 22).   No need to carry different meters for different areas, or worry about crossing through an Ex-required zone with a non-Ex rated instrument!

 

FLUKE 28 II EX True-RMS Specialty Meter:

Best for: Industrial troubleshooting in explosive environments.  Solving problems on motor drives, in plant automation, power distribution and electromechanical equipment.

With advanced capabilities:

  • Safety and compliance: Designed for use in dangerous or explosive atmospheres
  • Agency approvals: IECEx Ex ia IIC T4 Gb, Ex ia IIIC T130 °C Db, I M1 Ex ia I Ma
  • Designed for industrial troubleshooting

 

 

FLUKE 28 II Built For Your Environment:

  • A completely sealed, IP67 rated case
  • Withstands drops up to 10 ft or 3 m (with holster)
  • Dustproof per IEC60529 IP6x
  • Waterproof per IEC60529 IPx7
  • Meets IEC Overvoltage Electrical Safety Standard No. 61010-1:2001
  • Measurement Category III, 1000V, Pollution Degree 2
  • Measurement Category IV, 600V, Pollution Degree 2
  • Reversible holster for added protection of the display when not in use
  • Backlit keypad buttons provide extra visibility in poorly lit areas, even when you’re wearing full PPE
  • Large display digits and 2-level bright white backlight also increases visibility
  • Optional magnetic hanger for easy setup and viewing while freeing your hands for other tasks
  • Long battery life - 400 hours typical without backlight (Alkaline)
  • Access to the separate battery compartment makes it easy to change batteries or fuses without jeopardising instrument calibration

 

FLUKE 28 II Key Features:

  • 4-1/2 digit mode for precise measurements (20,000 counts)
  • True-rms ac voltage and current for accurate measurement on nonlinear signals
  • Measures up to 1000 V and 10A AC and DC (note that Ex zones require reduced measurements)
  • Low pass filter ensures accurate voltage and frequency measurements on variable speed motor drives (VSDs)
  • Frequency to 200 kHz and % duty cycle to help you diagnose VSDs and switching power supplies
  • Resistance, continuity and diode test
  • 10,000 μF capacitance range for components and motor caps
  • Conductance measurements for high resistance or leakage tests
  • Min/Max-Average and Peak capture to record transients and variations automatically
  • Relative mode to remove test lead interference on resistance measurements
  • Auto and manual ranging for maximum flexibility
  • Input Alert protects you by chirping and flashing “Lead when leads are plugged into the wrong inputs

 

What comes with the FLUKE 28II?

  • FLUKE 28 II Ex Intrinsically Safe Digital Multimeter
  • TL175 Test leads
  • AC175 alligator clips
  • 80BK-A temperature probe
  • Holster
  • Manual, CD-ROM
  • Three AA batteries (installed)

 

 

 

Comparison Chart for: Fluke 28 II Ex Intrinsically Safe Digital Multimeter

279 FC1587 FC28 II / 28 II Ex27 II
Basic featuresSpeciality MetersSpeciality MetersSpeciality MetersSpeciality Meters
Counts60006000200006000
True-rms readingsacacac
Basic dc accuracy0.09 %0.09 %0.05 %0.1 %
Wide bandwidth5 kHz20 kHz30 kHz
Auto / manual ranging
Digits3-1/24-1/23-1/2 / 4-1/23-1/2
ATEX II 2G Eex ia IICT4 safety rating Zone 1 and Zone 228 II Ex
Measurements
Voltage ac/dc1000 V1000V1000 V1000 V
Current ac/dc2500 A ac (with iFlex)400 mA10 A10 A
Resistance50 MΩ50 MΩ50 MΩ50 MΩ
Frequency100 kHz100 kHz200 kHz200 kHz
Capacitance10,000 µF10,000 µF10,000 µF10,000 µF
TemperatureInfrared Camera -10 ˚C to 200˚C(+) 537 °C(+) 1090 °C
Conductance60 nS60 nS
dB
Duty cycle / pulse width
Continuity / diode test
Motor Drive (ASD) Measurements
Microamps
Display
Fluke Connect enabled
Dot matrix display
Dual display
Analog bargraph
Backlight2 level2 level
Diagnostics and data
Min/Max recording / with time stamp
Fast min/max250 µs
Display Hold/Auto (Touch) Hold
Relative reference
Readings memories(With FC app)(With FC app)
USB interface
Other features
Removable holster
Infrared camera resolution80 x 60
Infrared camera Range-10 °C, +200 °C
iFlex compatibility
Insulation test voltages50 V, 100 V, 250 V, 500 V, 1000 V
Pi/DAR timed ratio test
Completely sealed and watertight
Operating temperature range-10 °C, +50 °C-20 °C, +55 °C-40 °C, +55 °C / -15 °C, +50 °C-40 °C, +55 °C
Warranty and electrical safety
Warranty Years33Lifetime / 3Lifetime
Input alert
Dangerous voltage indication
IP ratingIP 40IP 40IP 67IP 67
EN61010-1 CAT III1000 V1000 V1000 V1000 V
EN61010-1 CAT IV600 V600 V600 V600 V

 