258 Flue Gas Analyser


KANE 258 Flue Gas Analyser with direct CO & O2 measurement, CO sensor protection, pressure testing, temperature measurement & KANE LIVE connectivity.

Part Number:
KANE258

read more

 

Need Help ? Contact Us Request Demo
Acutest's Price Promise
  • Competitive quote
  • Expert technical advice/demos
  • Trusted aftercare support

Product Options

 

Manufacturer's RRP

£539.00
646.80 incl. VAT)
Add To Cart
  • Competitive quote
  • Expert technical advice/demos
  • Trusted aftercare support

 

 

 

KANE 258 Flue Gas Analyser with CO & O₂ Measurement

The KANE 258 Flue Gas Analyser is a domestic analyser and manometer designed for flue gas, pressure, temperature and combustion testing. It directly measures carbon monoxide (CO) and oxygen (O₂) and provides automatic CO over-range protection to help protect the CO sensor when high concentrations are encountered.

Alongside combustion analysis, the KANE 258 features a high-accuracy single pressure sensor to ±80 mbar, supporting flue draught, pressure, let-by and tightness testing. It also measures single, dual and differential temperature, bringing multiple testing functions together in one instrument.

A rotary dial and clear 6-line display provide straightforward access to test functions, while KANE LIVE connectivity enables results to be viewed, saved and sent digitally.

Contact our team for pricing, availability and further information on the KANE 258 Flue Gas Analyser.

Performing a gas tightness test using a Kane 258

 

Why Choose the KANE 258 Flue Gas Analyser?

The KANE 258 combines direct flue gas measurement with temperature and pressure testing for domestic appliance and combustion applications.

Direct CO measurement covers 0–2,000 ppm with over-range protection, while oxygen is measured from 0–21%. The analyser also calculates CO₂, CO/CO₂ ratio, excess air and combustion efficiency, providing key information for appliance safety and performance testing.

Automatic CO protection adds further protection for the sensor. When CO rises above the analyser‘s maximum measurement range, the sampling pump stops and the CO purge pump operates until levels fall sufficiently for normal measurement to resume.

 

KANE 258 Key Features:

  • Direct CO and O₂ measurement
  • CO measurement from 0–2,000 ppm
  • Automatic CO sensor over-range protection
  • Oxygen measurement from 0–21%
  • High-accuracy single pressure sensor to ±80 mbar
  • Single, dual and differential temperature measurement
  • Automatic let-by and tightness testing with KANE LIVE
  • Rotary dial and 6-line display
  • Connects to the KANE LIVE app
  • See, save and send test results
  • Optional printer connectivity
  • Protective rubber cover with magnets for hands-free use
  • KANE CARE Lifetime Warranty
  • Suitable for CCN1 or CCLP1, including CPA1, and CENWAT

 

Measures & Calculates:-

Measurements:

MeasurementRange / Function
Carbon Monoxide (CO)0–2,000 ppm with over-range protection
Oxygen (O₂)0–21%
Flue temperature0–600°C
Single, dual & differential temperatureYes
Pressure±80 mbar

 

Calculated Parameters:

  • Carbon Dioxide (CO₂): 0–20%
  • CO/CO₂ ratio
  • Excess air
  • Combustion efficiency

 

Automatic CO Sensor Protection

The KANE 258 Flue Gas Analyser incorporates automatic protection against high carbon monoxide concentrations.

If CO rises above the maximum measurement range, the analyser stops its sampling pump and activates the CO purge pump until CO levels fall below the maximum range.

 

Pressure & Temperature Testing

The KANE 258 is more than a combustion analyser. Its integrated pressure sensor supports flue draught and pressure tests, together with let-by and tightness testing. Automatic let-by and tightness tests can be carried out with the KANE LIVE app.

For temperature testing, the analyser supports single, dual and differential measurements. Type-K temperature probes can be connected to T1 and T2 for temperature and differential temperature testing.

 

Applications:

  • Domestic appliance testing
  • Combustion performance testing
  • Combustion efficiency testing
  • Flue draught testing
  • Pressure testing
  • Let-by testing
  • Tightness testing

 

Fuel Types:

  • Natural Gas
  • Butane
  • LPG
  • Light oil
  • Wood pellets
  • Propane

 

KANE LIVE Connectivity

Connect the KANE 258 Flue Gas Analyser to KANE LIVE to see, save and send test results from a compatible device.

Results can also be sent to an optional KANE printer, giving engineers a choice of digital or printed test records.

 

What Comes with the KANE 258?

Content of the Kane 258 Flue Gas Analyser

  • KANE 258 Flue Gas Analyser
  • CP2 probe
  • 3 rechargeable batteries
  • USB1 charger
  • MSC00237 protective case
  • 14102/2 carry bag

KANE 258 Kit Options:

  • PRO KIT
  • OIL KIT
  • CPA KIT

 

❓ Frequently Asked Questions (FAQ)

Q1: What does the KANE 258 measure?

A. It directly measures CO from 0–2,000 ppm and O₂ from 0–21%, as well as temperature and pressure. It also calculates CO₂, CO/CO₂ ratio, excess air and combustion efficiency.

Q2: Does the KANE 258 have CO sensor protection?

A. Yes. Automatic over-range protection stops the sampling pump and activates the CO purge pump when CO exceeds the maximum measurement range.

Q3: Can the analyser measure pressure?

A. Yes. The KANE 258 has a high-accuracy single pressure sensor to ±80 mbar.

Q4: Can it carry out let-by and tightness tests?

A. Yes. It supports let-by and tightness testing, including automatic let-by and tightness tests with the KANE LIVE app.

Q5: Does the KANE 258 have an integrity test function?

A. Simple watch the video below for a run through of it integrity test function.

Thumbnail for the KANE 258 Flue Gas Analyser Integrity Test Video

Note: Be sure to check the official datasheet before buying, and the user manual before using any test equipment. Need training? Just reach out - we’re happy to help.

 

Technical Specification for:

258 Kits:StandardPrinter Kit
Analyser
Probe
Pressure Connectors
Charger
Quick Guide Reference
Calibration Report
IRP-2 Infra-Red Printer
Carry Bag
Product Downloads

 

 

 

ONLY REGISTERED USERS CAN WRITE REVIEWS. PLEASE SIGN IN OR CREATE AN ACCOUNT