458s IAQ HVACR Flue Gas Analyser


KANE 458s IAQ HVACR Flue Gas Analyser for combustion, indoor air quality & HVACR testing, with CO, O2, CO2, pressure & wireless probe support.

Part Number:
KANE458S IAQ

read more

 

Need Help ? Contact Us Request Demo
Acutest's Price Promise
  • Competitive quote
  • Expert technical advice/demos
  • Trusted aftercare support

 

Manufacturer's RRP

£1299.00
1558.80 incl. VAT)
Add To Cart
  • Competitive quote
  • Expert technical advice/demos
  • Trusted aftercare support

 

 

 

KANE 458s IAQ HVACR Flue Gas Analyser

The KANE 458s IAQ HVACR Flue Gas Analyser combines flue gas analysis, indoor air quality testing and HVACR measurement capabilities in one versatile instrument for heating and cooling professionals.

Alongside direct O₂ and CO measurement, the analyser measures indoor air quality CO₂ up to 9,999 ppm, allowing both appliance and room testing for CO and CO₂. It also supports commercial direct and flueless appliance testing, timed room migration tests and appliance sweep tests.

For HVACR work, the KANE 458s IAQ HVACR can perform air conditioning and refrigeration tests using wireless smart probes, including superheat and subcool calculations. KANE LINK connectivity, KANE LIVE integration and structured testing functions bring combustion, IAQ and HVACR testing together in one professional platform.

Contact our team for pricing, configuration options and further information on the KANE 458s IAQ HVACR Flue Gas Analyser.

 

Why Choose the KANE 458s IAQ HVACR?

The KANE 458s IAQ HVACR is designed for engineers who work across heating, indoor air quality, ventilation, air conditioning and refrigeration.

Its IAQ CO₂ sensor enables CO and CO₂ testing on appliances and within rooms, including structured room migration timed tests and appliance timed sweep tests. It can be used for Type C sealed appliances, Type B open-flue boilers and Type A cookers, space heaters and water heaters.

For refrigeration and A/C work, compatible wireless probes allow testing without a conventional manifold and hoses, while calculated superheat and subcool values support HVACR system assessment.

 

KANE 458s IAQ HVACR Key Features:

  • Direct O₂ measurement from 0–21%
  • CO measurement from 0–10,000 ppm with H₂ compensation
  • IAQ CO₂ measurement from 0–9,999 ppm
  • H₂ measurement
  • Optional NO measurement from 0–600 ppm
  • Appliance CO and CO₂ testing
  • Room CO and CO₂ testing
  • Timed room migration testing
  • Timed appliance sweep testing
  • Commercial direct and flueless appliance testing
  • Differential pressure from -80 to +80 mbar
  • Differential temperature from -20°C to +1350°C with suitable probes
  • A/C and refrigeration testing with wireless probes
  • Superheat and subcool calculations
  • Connects to KANE LIVE
  • Supports KANE LINK
  • Data hold, logging and report printing
  • KANE LOCK stolen analyser protection
  • KANE CARE Lifetime Warranty

 

Measures & Calculates:-

Measurements:

MeasurementRange / Function
Oxygen (O₂)0–21%
IAQ Carbon Dioxide (CO₂)0–9,999 ppm
Carbon Monoxide (CO)0–10,000 ppm with H₂ compensation
Hydrogen (H₂)Measurement
Nitric Oxide (NO)0–600 ppm option
Differential temperature-20°C to +1350°C with suitable probes
Differential pressure-80 to +80 mbar
Air flow1.1–20 m/s with KANE-DTHA2 option
Temperature-20°C to +50°C with KANE-DTHA2 option
Relative humidity0.1–99% with KANE-DTHA2 option
Room CO0–999 ppm with KANE79 option

 

Calculated Parameters:

  • Flue gas CO₂
  • CO/CO₂ ratio
  • Excess air
  • Combustion efficiency
  • NOx with appropriate option
  • A/C and refrigeration superheat
  • A/C and refrigeration subcool

 

Indoor Air Quality & Appliance Testing

The integrated IAQ capability extends the analyser beyond conventional flue gas testing.

The KANE 458s IAQ HVACR can perform room tests for CO and CO₂, as well as appliance CO and CO₂ testing. Structured functions include timed room migration testing and timed appliance sweep testing using the IAQ CO₂ sensor.

It also supports testing of commercial direct and flueless appliances and kitchen appliance testing for CP42, CIS and BS8494.

 

HVACR Testing:

For air conditioning and refrigeration applications, the analyser works with compatible wireless smart probes to carry out HVACR testing without a traditional manifold, hoses or associated leaks.

It supports 40 refrigerants, including:

  • R22
  • R32
  • R134a
  • R290
  • R410A

Superheat and subcool are calculated as part of the A/C and refrigeration testing functions.

 

Fuel Types:

The analyser supports 12 standard fuels, including:

  • Natural Gas
  • LPG
  • Butane
  • Propane
  • Light Oil
  • Heavy Oil

A further 5 user fuels can also be configured.

 

Connectivity & Reporting

The KANE 458s IAQ HVACR can connect to KANE LIVE and compatible third-party apps, allowing test information to be managed digitally.

Test data can be held and logged, while reports containing user details can be sent to the optional KANE-IRP3 printer.

KANE LOCK provides additional analyser security by automatically disabling a stolen analyser.

 

What Comes with the KANE 458s IAQ HVACR?

Contents of the KANE 458s IAQ HVACR Gas Analyser

  • KANE 458s IAQ HVACR Flue Gas Analyser
  • CP2 probe
  • 3 rechargeable batteries
  • USB1 charger
  • MSC00237 protective case
  • 14102/2 carry bag

Available Kit Configurations

  • PRO KIT2
  • CPA KIT2
  • COM-CAT KIT
  • CMDDA KITS
  • HVACR KIT

A KANE-IRP3 printer is also available as an option.

 

❓ Frequently Asked Questions (FAQ)

Q1: What does the KANE 458s IAQ HVACR measure?

A. It measures O₂, CO, IAQ CO₂, H₂, differential pressure and differential temperature, with additional measurements available through compatible optional probes and sensors.

Q2: Can it test indoor air quality?

A. Yes. The analyser measures IAQ CO₂ up to 9,999 ppm and supports room CO and CO₂ tests, including timed room migration testing.

Q3: Can it be used for air conditioning and refrigeration?

A. Yes. With compatible wireless probes, it supports A/C and refrigeration testing and calculates superheat and subcool.

Q4: What is the CO measurement range?

A. The analyser measures CO from 0–10,000 ppm with H₂ compensation.

Q5: Does it support appliance CO and CO₂ testing?

A. Yes. It supports CO and CO₂ testing on appliances, including timed sweep testing and testing of Type A, Type B and Type C appliances.

Q6: Does it connect to KANE LIVE?

A. Yes. The analyser can connect to KANE LIVE as well as compatible third-party apps, with test data also available for logging and reporting.

Note: Be sure to check the official datasheet before buying, and the user manual before using any test equipment. Need training? Just reach out - we’re happy to help.

 

 

 

 