• approved distributor

    Buy or Hire Test Equipment
    Repair | Calibrate | Training

  • product advice and demos

    Product advice & demos
    Aftersales support

  • competetive prices

    Competitive quotes
    Bespoke deals

  • approved distributor

    Approved distributor
    Approved service centre

 

Be the first to review this product
(0)

Kane
9206 QUINTOX Emissions Monitoring Solution


Monitor industrial boiler emissions with the KANE9206 QUINTOX, featuring 5-gas sensing, optional toxic gas sensors & unattended testing.

Part Number:
KANE9206

read more

 

Need Help ? Contact Us Request Demo
Acutest's Price Promise
  • Competitive quote
  • Expert technical advice/demos
  • Trusted aftercare support

 

Manufacturer's RRP

£5939.00
7126.80 incl. VAT)
Add To Cart
  • Competitive quote
  • Expert technical advice/demos
  • Trusted aftercare support

 

 

 

KANE9206 QUINTOX Emissions Monitoring Solution

The KANE9206 QUINTOX Emissions Monitoring Solution is designed for industrial boiler commissioning, combustion analysis and emissions testing.

Featuring 5-gas sensor technology, the standard configuration measures O₂, CO₂, CO and HC, including both H₂-compensated CO measurement and high-range CO measurement up to 10%. Up to four additional toxic gas sensors can also be specified for applications requiring H₂S, NO, NO₂ or SO₂ measurement.

A high-suction pump supports testing on boilers with stack draught above 50 mbar, while a 64,000-test internal memory and remote handset make the analyser suitable for long-term unattended testing.

Contact our team for pricing, availability and guidance on the appropriate KANE9206 QUINTOX configuration for your emissions testing requirements.

 

Why Choose the KANE9206 QUINTOX?

The KANE9206 QUINTOX provides flexible industrial emissions monitoring with options to configure the analyser for different gases and testing environments.

Unattended boiler commissioning tests can be carried out with automatic fresh-air purge and the optional WTS9206P automatic water trap. For more advanced emissions work, optional gas conditioning, heated lines and heated probes are available.

Wireless and cable connections between the analyser and remote handset also allow measurements to be monitored away from the main instrument.

 

KANE9206 QUINTOX Key Features:

  • 5-gas sensor technology
  • Option to add up to 4 toxic gas sensors
  • High-suction pump for boilers with stack draught over 50 mbar
  • Up to 64,000 stored tests
  • Remote handset with wireless and cable connectivity
  • Large graphic display with 15 lines of text and data
  • Unattended boiler commissioning with automatic fresh-air purge
  • Main purge allows sensors to be zeroed and refreshed without removing the probe
  • Automatic sensor over-range protection
  • Optional gas conditioning for accurate NO₂ and SO₂ measurement
  • Optional sensor heater for cold-condition testing
  • Real-time monitoring and test transfer using KANE LIVE
  • Integral printer with optional KANE-IRP3 compatibility
  • Heavy-duty protective case
  • Lifetime warranty under KANE CARE Service & Recertification

 

Specifications:

Features 
O₂0–25%
CO₂0–21%
CO0–10,000 ppm H₂ compensated & 10% NDIR
HC0–5,000 ppm
Flue temperature0–1100°C
Pressure0–150 mbar
H₂S option0–1,000 ppm
NO option0–5,000 ppm
NO₂ option0–1,000 ppm
SO₂ option0–5,000 ppm
Internal memoryUp to 64,000 tests
ConnectivityWireless, cable & USB
Weight9.5 kg including heavy-duty case

 

Applications:

  • Industrial boiler emissions testing
  • Long-term unattended testing
  • Boiler commissioning
  • Combustion monitoring
  • High stack-draught applications
  • Marine engine emissions testing with appropriate sensor and accessory options

 

What Comes with the KANE9206 QUINTOX?

Contents of the KANE9206 QUINTOX

The analyser is supplied with:

  • Remote handset
  • Pressure connectors
  • PTFE-lined CHSP6 probe
  • CL5 USB lead
  • 19603 charger
  • Heavy-duty case

 

❓ Frequently Asked Questions (FAQ)

Q1: What gases does the KANE9206 QUINTOX measure?

A. The standard kit measures O₂, CO₂, CO and HC, with separate H₂-compensated and high-range CO measurement.

Q2: Can additional gas sensors be fitted?

A. Yes. Up to four optional sensors can be specified for H₂S, NO, NO₂ and SO₂.

Q3: Can it be used for unattended testing?

A. Yes. The analyser has capacity for up to 64,000 stored tests and supports unattended boiler commissioning.

Q4: Can it test boilers with high stack draught?

A. Yes. Its high-suction pump is designed for testing boilers with stack draught over 50 mbar.

Q5: Can measurements be monitored remotely?

A. Yes. The analyser includes a remote handset with both wireless and cable connectivity.

Q6: Does it work with KANE LIVE?

A. Yes. KANE LIVE can be used for real-time monitoring and transferring test results to compatible devices.

 

Get a Quote

For pricing, availability or further information on the KANE9206 QUINTOX Emissions Monitoring Solution, please contact our team.

Our test equipment specialists can provide guidance on toxic gas sensors, gas conditioning equipment, heated probes and other available accessories.

Note: Be sure to check the official datasheet before buying, and the user manual before using any test equipment. Need training? Just reach out - we’re happy to help.

 

 

 

 

ONLY REGISTERED USERS CAN WRITE REVIEWS. PLEASE SIGN IN OR CREATE AN ACCOUNT