ii1050 Acoustic Imager (air; gas; partial discharge detection)


Find compressed air, gas & vacuum leaks with the FLUKE ii1030 Acoustic Imager. Estimate leak costs, prioritise repairs & request a tailored quote now.

Part Number:
FLK-II1050

read more

 

Need Help ? Contact Us Request Demo
Acutest's Price Promise
  • Competitive quote
  • Expert technical advice/demos
  • Trusted aftercare support

 

Manufacturer's RRP

£16326.00
(£19591.20 incl. VAT)
Add To Cart
  • Competitive quote
  • Expert technical advice/demos
  • Trusted aftercare support

 

 

 

FLUKE ii1050 Acoustic Imager

Spot leaks and faults. Plan repairs with confidence.

The FLUKE ii1050 Acoustic Imager makes leak detection easier for maintenance teams. It locates compressed air leaks, gas leaks and vacuum leaks. It also helps detect partial discharge and early signs of mechanical faults.

See where sound comes from, even in noisy plants. Use its analysis tools to estimate leak costs, assess findings and create reports on the device.

Request a FLUKE ii1050 quote today. Tell us what you need to inspect.

 

From tracking down compressed air leaks that drain your budget...

Technician inspecting industrial pipework for compressed air leaks with a Fluke acoustic imager

 

...to revealing partial discharge before it becomes costly downtime.

Technician using the Fluke ii1050 acoustic imager to inspect substation equipment for partial discharge

 

 

FLUKE ii1050 Acoustic Imager Key Features:

  • SoundSight™ imaging: 202 microphones show sound sources on a camera image
  • LeakQ™: estimate leak rate and energy cost
  • PDQ Mode™: locate and assess partial discharge
  • MecQ™: check for bearing defects, friction and turbulence
  • Clear view: 7-inch touchscreen, 13 MP camera and 3× digital zoom
  • Simple reporting: add notes, asset details and repair priorities
  • Air-tightness checks: Beacon Mode works with the optional FLUKE SB140 SoundBeacon™
  • Portable design: IP54 protection and a weight of 1.2 kg with battery

 

Why choose the FLUKE ii1050 Acoustic Imager?

Check compressed air, gas and vacuum systems with one tool. Inspect switchgear, transformers, bearings, motors, pumps and fans.

Use leak cost estimates to choose which repairs to tackle first. Plan work early to help reduce unplanned downtime. Save notes and asset details to guide your team.

 

Features 
Microphone array202 digital MEMS microphones
Frequency band2 kHz to 100 kHz
Detection range0.5 m to more than 150 m, depending on ambient conditions
Typical field of view64° × 48° for the acoustic sensor and visible-light camera
Nominal frame rate25 frames per second
Visible-light camera13 MP; focus from 50 cm to infinity
Digital zoom3×
Display7-inch anti-glare, sunlight-readable LCD with backlight and capacitive touchscreen
Display resolution1280 × 800 pixels
Acoustic imageSoundMap™ overlay on the visible-light image
LeakQ™ ModeLeak size scale from 1 to 10, with leak rate and cost estimation
PDQ Mode™✓ partial-discharge source identification and probability estimation
PRPD display✓ real-time phase-resolved partial-discharge patterns
MecQ™ Mode✓ mechanical inspection for indicators of bearing defects, friction and turbulence
Beacon Mode✓ requires the optional FLUKE SB140 SoundBeacon™
Thermal imaging support✓ requires the optional FLUKE TC03A iSee™ Thermal Camera Attachment
Storage capacity128 GB
Image captureJPG with blended visible-light and SoundMap™ images
Video captureMP4 with blended visible-light and SoundMap™ images; up to 5 minutes per video
Reporting on the instrument✓
Inspection annotationsAsset details, text notes, action priorities and up to 4 photo notes
Asset identificationText entry and automatic QR code identification
ConnectivityWi-Fi and 2 × USB-C ports
Battery typeRechargeable, field-replaceable lithium-ion; 2 battery packs supplied
Battery lifeMore than 3.5 hours per battery; more than 7 hours across the 2 supplied batteries
ChargingInternal USB-C charging; less than 3 hours
Protection ratingIP54
Dimensions (H × W × L)235 × 154 × 46 mm
Weight1.2 kg including battery
Operating temperature-10 to +45 °C
Storage temperature-20 to +70 °C, with batteries removed
Relative humidity10 to 95 %RH, non-condensing
Operating altitudeUp to 2,000 m
Tripod connection1/4-inch-20 UNC thread
Microphone array health check✓ self-diagnostic notification when the array needs attention
Warranty2 years

 

What Comes with the FLUKE ii1050 Acoustic Imager?

Contents of the FLUKE ii1030 Acoustic Imager

  • FLUKE ii1050 Acoustic Imager
  • Hard carry case
  • Hand and neck straps
  • 2 × RRC2040 rechargeable battery packs
  • 65 W charger, USB-C cable and country-specific connectors

The FLUKE TC03A thermal attachment and SB140 SoundBeacon™ are optional extras.

 

FLUKE ii1050 Kit Bundle Options

Expand your inspection capabilities with a thermal camera kit, or choose a package with SoundBeacon™. All options include the standard ii1050 package, plus the extras below.

All kits include the standard ii1050 package, plus the additional accessories shown below.

Additional accessoriesFLK-II1050/T9HZFLK-II1050/T50HZFLK-II1050/9H/SB140FLK-II1050/50H/SB140
TC03A thermal camera9 Hz50 Hz9 Hz50 Hz
TP01 II-Series tripod✓ Included in all kits
SB140 SoundBeacon™ (40 kHz)—✓

 

❓ Frequently Asked Questions (FAQ)

Q1: Does it include thermal imaging?

A. Thermal imaging needs the optional FLUKE TC03A iSee™ attachment. It is also available in selected ii1050 bundles.

Q2: What do I need for air-tightness tests?

A. Use Beacon Mode with the optional FLUKE SB140 SoundBeacon™ transmitter to check for sealing defects.

Q3: How long do the batteries last?

A. Each battery lasts more than 3.5 hours. The two supplied packs provide more than 7 hours in total.

 

Request a Quote for the FLUKE ii1050 Acoustic Imager

Tell us what you need to inspect, how many units you need and which accessories you want.

Enquire today for your FLUKE ii1050 Acoustic Imager quote.

Note: Be sure to check the official datasheet before buying, and the user manual before using any test equipment. Need training? Just reach out - we’re happy to help.

 

Technical Specification for:

Product Downloads

 

 

 

ONLY REGISTERED USERS CAN WRITE REVIEWS. PLEASE SIGN IN OR CREATE AN ACCOUNT