Clare
HAL101 AC/DC Hipot & DC Insulation Tester


The ClareHAL 101 is an advanced insulation tester. Its features include AC and DC hipot, DCIR and arc detection along with an internal memory.

Part Number:
HAL101

read more

 



List Price:

£2636.00
3163.20 incl. VAT)

Get in touch for our best price

Request a Quote
or

Bulb On Icon

Training
Courses
Available

Best Practice Course
Product Specific Course
Tailored for your business needs
read more

 

 

ClareHAL 101

Advanced Multi-function Safety Tester

  • AC and DC hipot, DCIR and arc detection
  • Internal memory
  • Intuitive user interface

The ClareHAL 101 is a programmable hipot & DC IR tester. Isolated floating test outputs make it probably the safest hipot tester on the market. The user interface enables it to be used manually within laboratory, audit and product compliance environments. Use with a barcode scanner will automate the production flow and enable the product to be linked directly into most ISO quality systems.

Various accessories including label printers and an internal memory to store up to 6000 test records make the ClareHAL 101 very versatile. Separate software enables download to PC for further analysis or SPC. Automatic test sequences are configurable and the tester can be controlled from a host device via RS232, or external PLC I/O ports making it ideal for system integration.

Technical specification

AC Flash/Hipot Test

Voltage Range 0.100 – 5.000kV (programmable)
Voltage Resolution 10V/step (settable)
Voltage Accuracy 1% of reading +/- 2 digits
Maximum Output Current 20mA @5kV 50/60 Hz Selectable
Display Current Range 0.01 – 20.00mA
Current Accuracy 1% of reading +/- 2 digits
Display Current Resolution 0.01mA

DC Flash/Hipot Test

Voltage Range 0.100 – 6.000kV (programmable)
Voltage Resolution 10V/step (settable)
Voltage Accuracy 1% of reading +/- 2 digits
Maximum Output Current 10mA @6kV
Display Current Range 0.01 – 10.00mA
Current Accuracy 1% of reading +/- 2 digits
Display Current Resolution 0.01mA
Output Ripple < 5% @ 6kV

DC Insulation Resistance

DC Output Voltage 250, 500 or 1000V selectable, or fully adjustable from 10 – 1000V
Resistance Ranges Measurement 0.50 – 99.99MOhm and 100.0M – 999.9MOhm
Resistance Ranges (Accuracy) +/-5% of reading, +/- 2 digits (25kOhm - 500MOhm), >500MOhm Indication only

ARC Detection

Detect Current 10 Levels

Environmental

Operating Temperature 0°C to +40°C
Storage Temperature -10°C to +60°C
Humidity Non condensing (<75% max. non condensing)

Mechanical

Dimensions 370 x 300 x 204 mm
Weight 12kg approx

 

Technical Specification for: Clare HAL101 AC/DC Hipot & DC Insulation Tester

No data for this product
General Specifications

 

Accessory Code Description Price (Ex VAT)
03918/2 HT Probe - Red £68.00 ADD
03919/2 HT Probe Yellow with HT Plug £73.00 ADD
194A922-C Barcode Scanner £155.00 ADD
312A916 Desk Test 'n' Tag Printer £528.00 ADD
39044 Mains Plug £37.00 ADD
CON 965/LINK Guard Plug Link £41.00 ADD
DCS317 Guard Switch £55.00 ADD
H-5003 HT Output Clip Lead Sub Assembly £38.00 ADD
H-5009 Class I Output Socket Box Hal 101 / 102 only £174.00 ADD
H-5014 Comms Lead £39.00 ADD
H-5017 Status Beacon - HAL Series £212.00 ADD
H-5022 Class II Output Socket Box Hal 101 / 102 only £174.00 ADD
H-5030 Printer Lead (Desk Test 'n' Tag) £47.00 ADD
Y160H Fault Simulator £121.00 ADD

PAT Training 1/2 Day more info
Portable Appliance Testing Awareness Course

Become trained in PAT Testing - 1/2 day course for up to 6 people
(if you have fewer or more people call us for pricing)*

The course starts with an introduction to the subject of PAT and an overview of the functions and operation of the test instruments required. The course then develops to look at the types of appliances and classes of equipment usually encountered and the tests which are applied to each appliance. Each test will be demonstrated using sample equipment and delegates will have the opportunity to use and operate the test instruments and much more...

PAT Training 1 Day more info
Portable Appliance Testing Awareness Course

Become trained in PAT Testing - One day course for up to 6 people
(if you have fewer or more people call us for pricing)*

The half-day course can be expanded to a full day in one of two ways –
1. Additional time to consolidate the information acquired in the morning and further practice on the inspection & test process
2. Product training on the client’s own PAT tester

2377 22 & 32 PAT Training & Management more info
Req. for the Maintenance of Electrical Equipment

City & Guilds 2377 22 & 2377 32 Portable Appliance Testing & Management. 3 day course. The aim of this qualification is to enable you to undertake practical inspection and testing of electrical equipment. This qualification specifically addresses the requirements of the IEE Code of Practice for In-Service Inspection and Testing of Electrical Equipment.

This 3 day course also includes the 2377-32 qualification (Management Requirements for the maintenence of Electrical Equiptment)

  • Cost £435.25 for 1 attendee(s)

2377 22 PAT Training more info
Inspection & Testing of Electrical Equipment

City & Guilds 2377 22 Portable Appliance Testing Course. 2 1/2 day course. The aim of this qualification is to enable you to undertake practical inspection and testing of electrical equipment. This qualification specifically addresses the requirements of the IEE Code of Practice for In-Service Inspection and Testing of Electrical Equipment.

  • Cost £335.25 for 1 attendee(s)

Product Training 1/2 Day more info
Product Awareness Course

Get to know your new purchase! Maximise your return on investment with product and software training modules!

A lack of product training can result in under-utilisation of test equipment, low return on investment and, most importantly, incorrect use.

Product Training 1 Day more info
Product Awareness Course

Get to know your new purchase! Maximise your return on investment with product and software training modules!

A lack of product training can result in under-utilisation of test equipment, low return on investment and, most importantly, incorrect use.